Wakeup client settings
Installer and configuration settings for the WakeUp client module of the 1E Client supported only on Windows computers.
Note
Note
Installer properties for Windows:
Module.WakeUp.Enabled | Module.WakeUp.ManageFirewallRules | MODULE.WAKEUP.ADDITIONALSUBNETS | MODULE.WAKEUP.AGENTTCPPORT | MODULE.WAKEUP.AGENTTO | MODULE.WAKEUP.ALLOWLASTMANSUSPEND | MODULE.WAKEUP.CERTISSUER | MODULE.WAKEUP.CERTSUBJECT | MODULE.WAKEUP.DEBUG | MODULE.WAKEUP.DELAYCYCLESMSSECS | MODULE.WAKEUP.ENCRYPTIONLEVEL | MODULE.WAKEUP.LASTMANENABLED | MODULE.WAKEUP.LOGFILENAME | MODULE.WAKEUP.LOGPATH | MODULE.WAKEUP.MAGICPACKETDELAY | MODULE.WAKEUP.MAGICPACKETPORT | MODULE.WAKEUP.MAXIMUMFILEAGESECS | MODULE.WAKEUP.MAXLOGFILESIZE | MODULE.WAKEUP.REFRESHHWINFOAFTERHOURS | MODULE.WAKEUP.REFRESHONSUBNETCHANGE | MODULE.WAKEUP.REPEATCOUNT | MODULE.WAKEUP.REPEATDELAY | MODULE.WAKEUP.REPORTING | MODULE.WAKEUP.REPORTINGSERVER | MODULE.WAKEUP.SECUREREPORTINGSERVER | MODULE.WAKEUP.SENDHARDWAREINFO | MODULE.WAKEUP.SPOOLDIR | MODULE.WAKEUP.STAYONFROMSTANDBYMINS | MODULE.WAKEUP.SUBNETOVERRIDE | MODULE.WAKEUP.TCPPORT | MODULE.WAKEUP.USEFIPS | MODULE.WAKEUP.WAKEDISPLAYAFTERSTANDBY | MODULE.WAKEUP.WURESULTDELAY
Note
1E Client installers include a template configuration file that contains the more important settings with default values that match hard-coded default values. The configuration file is updated during installation and named 1E.Client.conf in the installation folder along with the 1E Client executable.
After installation, configuration file settings can be managed using 1E Client reconfiguration, Endpoint Troubleshooting configuration instructions, Endpoint Automation policies, Configuration Manager baselines or other means. Registry settings can also be managed by Windows Group Policy.
Note
The WakeUp client module of the 1E Client replaces the 1E Agent WakeUp components of the 1E Agent and 1E WakeUp Server.
If the WakeUp Server is configured in multi-agent mode (recommended) then the 1E Client must be installed with the WakeUp client module enabled on all in-scope devices.
When the 1E Client starts, and the WakeUp client module is enabled, it will only initialize the WakeUp client module if the OS version is Windows 7 or later. The 1E Client will automatically remove any previous installation of the WakeUp component from the 1E Agent, leaving behind the NightWatchman component, and keeping the WakeUp Agent registry settings. For NightWatchman v7.2.500 onwards the NightWatchman Agent has a separate installer, and its settings continue to be managed by the NightWatchman Management Center Web Service.
The WakeUp Server also requires a local WakeUp Agent, and therefore requires the 1E Client to be installed with the WakeUp client module enabled. The WakeUp Server is a 32-bit process and its registry entries are in the 32-bit WOW6432Node area. The 1E Client is a 64-bit process with its registry entries in the 64-bit area. When the 1E Client starts, if the WakeUp client module is enabled the 1E Client will automatically remove any previous installation of the WakeUp Agent component, leaving behind the WakeUp Server component, and moving the existing WakeUp Agent registry settings from the 32-bit to the 64-bit area of the registry.
WakeUp and the WakeUp client module of the 1E Client do not require a full Tachyon infrastructure; only the 1E Client is required, Tachyon Servers are not required. The full Tachyon infrastructure is required only if you are integrating NightWatchman with Tachyon.
The WakeUp client module of the 1E Client is not supported on:
Non-Windows devices
Legacy OS (that is OS which Microsoft no longer support including Windows XP, Vista, 7, Server 2008 etc.)
The following legacy WakeUp features from the 1E Agent do not exist in the WakeUp client module:
1E WakeUp Agent service - all WakeUp Agent features are now implemented as the WakeUp client module in the 1E Client service
Computer Health feature - is now obsolete
WakeUp client installation settings
The table below lists the configuration properties required to enable the WakeUp client required for integration with NightWatchman Enterprise v7.2.500 or later.
Note
You must use UPPERCASE when specifying the name of any installer property in a mst transform file, and preferably when including them in a msiexec command-line.
Names of settings stored in the configuration file are not case-sensitive. Setting names stored in the registry may be case-sensitive and should be specified as shown.
Settings that have numeric values must be set using decimal integers, unless otherwise specified.
1E Client configuration setting | Installation default | Description |
---|---|---|
false | Set this property to true to enable the WakeUp client module. The default value is false. Enabling this will also cause any installation of the 1E Agent's WakeUp component to be uninstalled the first time the 1E Client is started, leaving the NightWatchman component if that was installed. NoteWhen true then you must also specify either the name of the NightWatchman Management Center reporting server, or that reporting is turned off. For details of these and all other installer properties please refer to WakeUp client settings. | |
true | Set this property to true to enable the Windows firewall domain rule. The default value is true. A Windows firewall domain rule called 1E Client is removed/added each time the 1E Client is stop/started. |
WakeUp client registry settings
The table below lists additional settings for the WakeUp client module, which may be specified during installation of the 1E Client as Windows installer properties in upper-case. They are stored in the registry in mixed-case. They are not stored in the 1E Client configuration file, and cannot be reconfigured after installation using 1E Client command-line parameters. The registry values can be updated via group policy object (GPO) administrative templates or other means.
Note
The table indicates where installer properties have a different name to the registry setting. In some cases this is for backwards compatibility with previous 1E Agent installer properties.
In the descriptions below, the term WakeUp Agent is used to describe the WakeUp client module of the 1E Client. The terms Primary Agent and Alternate Agent are WakeUp roles.
Note
You must use UPPERCASE when specifying the name of any installer property in a mst transform file, and preferably when including them in a msiexec command-line.
Names of settings stored in the configuration file are not case-sensitive. Setting names stored in the registry may be case-sensitive and should be specified as shown.
Settings that have numeric values must be set using decimal integers, unless otherwise specified.
1E Client installer property | Installation default | Description | Registry name | Registry type |
---|---|---|---|---|
NoteThe registry value is not created unless the installation property is specified. | Used only in dedicated agent mode. It enables the dedicated WakeUp Agent to register to awaken multiple subnets. It requires that directed subnet broadcasts are enabled in the routers between the agent and remote subnets. It takes a comma delimited list of subnets. Its use and format are described in WakeUp documentation for NightWatchman Enterprise: Configuring network access control security. | \AdditionalSubnets | REG_SZ | |
NoteThe registry name is different to the installer property name (it has an underscore). | 1776 | The listening port used by the WakeUp Server to communicate with the WakeUp Agents. Default value is 1776 (decimal). NoteThe AgentTCP_Port value must be different to the TCP_Port value, and must be the same for the WakeUp Server and all Agents. | \AgentTCP_Port | REG_DWORD |
Set to enable Dedicated Agent mode. This parameter should be set to the FQDN (recommended) or NetBIOS name of the WakeUp Server. Default is empty to enable Multi-Agent mode. Dedicated Agent mode does not have Multi-Agent features. | \AgentTo | REG_SZ | ||
1 | Set to 0 if you want to allow a Primary or Alternate Agent to respect Microsoft power schemes and go to sleep. Set to 1 (default) to prevent a Primary or Alternate Agent going to sleep. NoteThe value of this property is the opposite to what its name implies. | \AllowLastManSuspend | REG_DWORD | |
Specify the text used to search for a client certificate in the client certificate store. Either MODULE.WAKEUP.CERTISSUER or MODULE.WAKEUP.CERTSUBJECT is mandatory when all the following are true:
If this property is used, it will use the first certificate it finds where the specified text matches the certificate's Issuer CN. | \Reporting\HTTPS\CertIssuer | REG_SZ | ||
Specify the text used to search for a client certificate in the client certificate store. Either MODULE.WAKEUP.CERTISSUER or MODULE.WAKEUP.CERTSUBJECT is mandatory when all the following are true:
If this property is used, it will use the first certificate it finds where the specified text matches the certificate's Subject CN. | \Reporting\HTTPS\CertSubject | REG_SZ | ||
13 | Sets the level of debug information output to the WakeUp Agentlog file. Default value is 13 (decimal). Range is 1 to 255 (decimal). You should only change this value if requested by 1E Support, and reset it back to 13 when investigation is completed. | \Debug | REG_DWORD | |
16 | Delay (in seconds) before the WakeUp Agent performs a policy refresh after receiving a policy refresh instruction from the WakeUp Server via the Primary Agent. This delay allows time for the ConfigMgr Management Point to be updated in instances where Advertisements are newly created. Default value is 16. | \DelayCycleSMSSecs | REG_DWORD | |
0 | The encryption level used in communications between WakeUp Agents and WakeUp Servers. This does not affect encryption used for WakeUp Reporting.
NoteIf the MODULE.WAKEUP.USEFIPS installer property is set to 1 it will override the MODULE.WAKEUP.ENCRYPTIONLEVEL installer property and sets the EncryptionLevel registry value to 3, and also uses FIPS for WakeUp Reporting by setting the UseFipsComplianceEncryption registry value to 1. When configuring this option you will need to ensure that the same setting is made for all WakeUp Agents and WakeUp Servers. Care is required when migrating Agents from Off (0) to On (2) or the other way round, then the WakeUp Servers will need be configured to support both, by temporary use of of partial/mixed encryption (1). Once you are sure all Agents are configured to the same setting, then you should change the WakeUp Server to match the Agents' setting. WakeUp does not support partial/mixed use of FIPS (3) and EncryptionLevel (0/2) therefore all NightWatchman and WakeUp Servers and Agents must be configured to use FIPS from the outset, or all changed at the same time. EncryptionLevel and FIPS settings used by WakeUp do not affect other 1E Client communications. | \EncryptionLevel | REG_DWORD | |
1 | Determines if the WakeUp last man standing functionality is turned on or off.
| \LastManEnabled | REG_DWORD | |
NoteThe registry name is the same as the installer property name but contains a combination of LOGPATH and LOGFILENAME installer properties. | WakeUpAgt.log | The name of the WakeUp Agent log file. This combines with LOGPATH to give the LogFileName registry value. | \LogFileName | REG_SZ |
NoteSee LOGFILENAME. | %ALLUSERSPROFILE%\1E\Agent | The location of the WakeUp Agent log file. This combines with LOGFILENAME to give the LogFileName registry value. | NoteSee LOGFILENAME | |
1 | The delay (in milliseconds) between the WakeUp Agent sending subsequent Magic Packets. Default value is 1. | \MagicPacketDelay | REG_DWORD | |
NoteThe registry name is different to the installer property name (it has an underscore). | 1776 | The UDP port used to send wake up broadcasts. Default value is 1776 (decimal). | \MagicPacket_Port | REG_DWORD |
1209600 (14 days) | Sets the maximum age (in seconds) for the Agent to retain reporting information locally when the NightWatchman Management Center Web Service cannot be contacted. By default, this is set to 1209600 seconds (14 days). Any files older than that will not be submitted to the NightWatchman Management Center Reporting and will be deleted instead. This value need not be modified under normal circumstances. | \Reporting\MaximumFileAgeSecs | REG_DWORD | |
1048576 (1MB) | Maximum size (in bytes) for the WakeUp Agent log file. There are 5 rollover files numbered 1 (newest) to 5 (oldest) with the rollover number included as n.log (In previous versions of WakeUp the .LOG file was renamed with a .LO_ extension and a new .LOG file is created. The .LO_ file is overwritten each time.) | \MaxLogFilesize | REG_DWORD | |
720 (30 days) | The frequency (in hours) for hardware inventory details to be sent to the NightWatchman server if WakeUp reporting is enabled (default) and MODULE.WAKEUP.SENDHARDWAREINFO=ON. Range is from 24 to 999. The default is 720 (30 days). If the NightWatchman Agent is also installed, it will send hardware inventory more frequently. | \Hardware\RefreshHwInfoAfterHours | REG_DWORD | |
ON | Triggers the local ConfigMgr client to do a Hardware Inventory Cycle when the WakeUp Agent detects a change of subnet. The client in turn, updates the ConfigMgr Site inventory, thereby enabling the Site's WakeUp Server to have the latest subnet details.
TipThis is particularly useful where laptops move between offices. Typically, Wake-On-LAN is not supported over wireless, therefore IGNOREWIRELESS avoids the overhead of triggering a ConfigMgr hardware inventory for wireless changes. Use OFF only if you are sure computers will not change subnet, and you can rely on the normal ConfigMgr inventory cycle. The WakeUp system relies on having the latest subnet details in order to wake computers. The WakeUp Agent updates the NightWatchman database with all subnet changes, because the NightWatchman server is designed to support frequent updates. | \RefreshOnSubnetChange | REG_SZ | |
0 | Number of times to repeat sending Magic Packets. Default is 0. NoteIf you suspect that your network is prone to dropping datagram packets you should try different configurations for | \RepeatCount | REG_DWORD | |
0 | Delay (in milliseconds) before resending a repeated Magic Packet. Default is 0. NoteIf you suspect that your network is prone to dropping datagram packets you should try different configurations for | \RepeatDelay | REG_DWORD | |
ON | Enables WakeUp reporting. Sets whether the Agent sends reporting messages to the NightWatchman Management Center Web Service. May be set to one of the following values:
TipWhen installing the 1E Client on a WakeUp Server, set MODULE.WAKEUP.REPORTING=OFF so that the server does not appear as a client in the NightWatchman Management Center Admin Console. This will only disable Agent reporting whilst the WakeUp Server will have reporting enabled for reporting statistics. | \Reporting | REG_SZ | |
NoteThe registry name is different to the installer property name. The supplied value is converted into a full URL. | Set this parameter to the FQDN (recommended) or NetBIOS name of the server hosting the NightWatchman Management Center Web Service. WarningMandatory when WakeUp reporting is enabled (default) and using HTTP for communications. TipIf HTTP is not using standard port 80 then specify the port number as part of the server name: MODULE.WAKEUP.REPORTINGSERVER="ACMESERVER.ACME.COM:8080" | \Reporting\HTTP\ServiceUrl | REG_SZ | |
NoteThe registry name is different to the installer property name. The supplied value is converted into a full URL. | Set this parameter to the FQDN (required) or NetBIOS name of the server where the NightWatchman Management Center Web Service component secure site has been installed. WarningMandatory when WakeUp reporting is enabled (default) and using HTTPS for communications. TipIf HTTPS is not using standard port 443 then specify the port number as part of the server name: MODULE.WAKEUP.SECUREREPORTINGSERVER="ACMESERVER.ACME.COM:7433" | \Reporting\HTTPS\ServiceUrl | REG_SZ | |
NoteThe registry name is different to the installer property name. | ON | Enables hardware information messages to be sent to the NightWatchman server, if MODULE.WAKEUP.REPORTING=ON. See also MODULE.WAKEUP.REFRESHHWINFOAFTERHOURS. | \Modules\HwInfoAgt | REG_SZ |
NoteThe registry name is different to the installer property name. | %ALLUSERSPROFILE%\1E\Reporting\WakeUp\ | The location of the WakeUp spooler directory, where Reporting messages are stored before being sent to the NightWatchman Management Center Web Service. The location should not need to be modified under normal circumstances. Default value is%ALLUSERSPROFILE%\1E\Reporting\WakeUp\ | \Reporting\SpoolerDirectory | REG_SZ |
0 | Set this to the number of minutes the Wakeup Agent keeps the OS awake after a wakeup. This is to allow sufficient window of time for multiple jobs to run. If set to less than or equal to 0 (default) then the WakeUp Agent will keep the OS awake for 20 minutes. Set this this value to more than 20 to keep the OS awake for longer. | \StayOnFromStandbyMins | REG_DWORD | |
NoteThe registry value is not created unless the installation property is specified. | Contains a list of all unauthenticated subnets that correspond to the authenticated subnets for which the Agent is responsible. Its use and format are described in WakeUp documentation for NightWatchman Enterprise: Configuring network access control security. | \SubnetOverride | REG_SZ | |
NoteThe registry name is different to the installer property name (it has an underscore). | 1777 | The listening port used by the WakeUp Agents to communicate with the WakeUp Server. Default value is 1777 (decimal). NoteThe TCP_Port value must be different to the AgentTCP_Port value, and must be the same for the WakeUp Server and all Agents. | \TCP_Port | REG_DWORD |
NoteThe registry name is different to the installer property name. | 0 | Set to 1 to force the WakeUp agent to use a FIPS-compliant algorithm for:
If enabled, then all components in the NightWatchman and WakeUp system must have FIPS enabled. EncryptionLevel and FIPS settings used by WakeUp do not affect other 1E Client communications. | \Reporting\UseFipsComplianceEncryption | REG_DWORD |
0 | Set to 1 to force the display to come on (assuming it has power) after it has been woken up. This feature works in conjunction with MODULE.WAKEUP.STAYONFROMSTANDBYMINS. | \WakeDisplayAfterStandBy | REG_DWORD | |
0 | The time (in seconds) the WakeUp Primary Agent allows for responses to magic packets before it tries to pings devices that have not yet responded with a WASAWAKE or JUSTWOKE and then report NOAGENT or FAILED to the WakeUp Server for reporting purposes. This is especially useful when trying to wake devices that do not have the WakeUp client module enabled. The delay should be set to how long it normally takes for devices to start up. If set to 0 the WakeUp Server determines the time, but this can be overridden by changing the value on the WakeUp Primary Agent. In multi-agent mode, this effectively means all Agents. | \WUResultDelay | REG_DWORD |
The following table is for WakeUp client module registry values that do not have Windows installer properties, and are not stored in the 1E Client configuration file.
Warning
These registry values are reserved for use by the WakeUp client module and must not be modified.
Registry name | Registry type | Description |
---|---|---|
\AgentRegInfo | REG_SZ | Used by the Primary and Alternate Agent to store information it has registered with the WakeUp Server. |
\AltAgentMacAddress | REG_BINARY | Used by the Primary and Alternate Agent to store each other’s MAC address details. |
\InstallationDirectory | REG_SZ | Used as a record of the installation folder, for backwards compatibility. |
\MiniAgentTo | REG_SZ | Used by the Primary and Alternate Agent to store the NetbiosName of the 1E Wakeup Server. |
\PatchLevel | REG_SZ | Used to indicate the version of the most recent software patch installed. |
\TachyonAgentVersion | REG_SZ | Used as a record of the 1E Client version that created the registry settings. |